Red Light Routine
SoleGlow Recovery Slides
SoleGlow Recovery Slides
Couldn't load pickup availability
30-day returns • One-year limited warranty • Secure checkout
A future-facing wearable light concept.
An early-stage illuminated footbed concept for seated wellness use only. Production engineering, fit, and exposure conditions require prototype validation before sale.
Red Light Ritual | Proposed Engineering Specification
Product-development targets — not verified specifications of currently supplied inventory. This document defines characteristics a manufacturer must meet before a finished device may be represented as having them.
| Emitter technology | Non-laser LED photobiomodulation architecture (target) |
|---|---|
| Target peak wavelengths | 660 nm red + 850 nm near-infrared |
| Target irradiance | 10–25 mW/cm² (combined, subject to lab verification) |
| Measurement condition | At footbed interface; measure spatial uniformity under representative contact |
| Target operating modes | Red / NIR / combined; low-output default; 5 / 10 min auto-off |
| Target construction | Low-voltage integrated footbed; seated-use interlock target; rechargeable electronics |
| Safety validation | Prototype validation, temperature and pressure testing, liquid ingress evaluation and optical-safety assessment |
| Electrical ratings / dimensions / LED count | To be finalized in supplier engineering drawings and test reports |
| Certification / regulatory status | Not established; verify for each intended market and claim |
Engineering Acceptance Criteria
- Supplier must provide spectral measurements identifying peak wavelength and tolerances for each emitter channel.
- Optical irradiance must be measured using calibrated equipment at the stated position, with spatial uniformity data and test conditions reported.
- Provide electrical power ratings, temperature-rise results, materials information, operating instructions, and relevant safety and compliance documentation.
- Do not substitute LED electrical wattage for measured optical output.
- Finalize session duration, dosage, eye protection and contraindications based on device-specific assessment.
Important Product Status
Numbers above describe the intended sourcing and manufacturing specification. They are not measurements, test results, regulatory clearances or performance claims for this listing's current item. Availability for sale and final customer-facing claims must be reviewed against the actual manufactured device and applicable requirements.
Not intended to diagnose, treat, cure or prevent disease. Follow the validated user instructions; seek appropriate professional guidance for light-exposure concerns.