Product-development targets — not verified specifications of currently supplied inventory. This document defines characteristics a manufacturer must meet before a finished device may be represented as having them.
| Emitter technology | Non-laser LED photobiomodulation architecture (target) |
|---|---|
| Target peak wavelengths | 660 nm red + 850 nm near-infrared |
| Target irradiance | 60–100 mW/cm² (combined, subject to lab verification) |
| Measurement condition | At 15 cm; specify calibrated test grid, average and peak |
| Target operating modes | Red / NIR / combined; dimming; 5 / 10 / 15 / 20 min timer |
| Target construction | Ventilated tabletop enclosure; adjustable stand; external power supply |
| Safety validation | Photobiological hazard classification, thermal management, EMC and electrical safety testing |
| Electrical ratings / dimensions / LED count | To be finalized in supplier engineering drawings and test reports |
| Certification / regulatory status | Not established; verify for each intended market and claim |
Engineering Acceptance Criteria
- Supplier must provide spectral measurements identifying peak wavelength and tolerances for each emitter channel.
- Optical irradiance must be measured using calibrated equipment at the stated position, with spatial uniformity data and test conditions reported.
- Provide electrical power ratings, temperature-rise results, materials information, operating instructions, and relevant safety and compliance documentation.
- Do not substitute LED electrical wattage for measured optical output.
- Finalize session duration, dosage, eye protection and contraindications based on device-specific assessment.
Important Product Status
Numbers above describe the intended sourcing and manufacturing specification. They are not measurements, test results, regulatory clearances or performance claims for this listing's current item. Availability for sale and final customer-facing claims must be reviewed against the actual manufactured device and applicable requirements.